Vinka foutmeldingen
NO. | Error Name | Error Code | Appearance | Discription | Advice for user | Advice for after-sales service |
0 | TorqueZeorError | 0x90 | Stop motor output | Torque sensor issue | 1. Deal by user a. Padel reverse b. Re-power the e-bike 2. Repaired by after-sales service | 1. Change torque sensor 2. Change motor controller unit |
1 | TorqueOutRange | 0x11 | Stop motor output | Torque sensor issue | 1. Deal by user a. Repower the ebike 2. Repaired by after-sales service | 1. Change torque sensor 2. Change motor controller unit |
2 | TorqueSensorFault | 0x92 | Switch to cadence mode | Torque sensor issue | 1. Repair by after-sales service | 1. Change torque sensor 2. Change motor controller unit |
3 | GearSensorError | 0x13 | Report error only | Gear sensor issue | 1. Repair by after-sales service | 1. Change Gear Sensor |
4 | SpeedSensorError | 0x15 | Report error only | Speed sensor issue | 1. Deal by user a. Adjust the position of speedsensor and steel magnet 2. Repaired by after-sales service | 1. Adjust the position of speedsensor and steel magnet 2. Change speed sensor |
5 | CadenceError | 0x18 | Stop motor output | Cadence sensor issue | 1. Repair by after-sales service | 1. Change cadence sensor |
6 | PcbOverTempWarning | 0x20 | Reduce motor output | Motor high temperature | 1.Deal by user a.Reduce assist level 2.Repaired by after-sales service | 1. Change motor controller unit |
7 | PcbOverTempError | 0xA1 | Stop motor output | Motor overheat | 1.Deal by user a.Power off and wait for the motor cool down 2.Repaired by after-sales service | 1. Change motor controller unit |
8 | PcbSensorFault | 0x22 | Reduce motor output | Temperature sensor issue | 1. Repair by after-sales service | 1. Change motor controller unit |
9 | MotorOverTempWarning | 0x25 | Reduce motor output | Motor high temperature | 1. Deal by user a.Reduce assist level 2. Repaired by after-sales service | 1. Change motor controller unit |
10 | MotorOverTempError | 0xA6 | Stop motor output | Motor overheat | 1. Deal by user a. Power off and wait for the motor cool down 2. Repaired by after-sales service | 1. Change motor controller unit |
11 | FlashError | 0xA7 | Stop motor output | Motor internal flash error | 1. Deal by user a.Re-power the e-bike 2. Repaired by after-sales service | 1. Reset motor parameter to default by Dealer tool 2. Change motor controller unit |
12 | CommunicationLost | 0x80 | Stop motor output | Motor Communication issue | 1. Deal by user a. Re-power the e-bike b. Check the connection between display and motor 2.Repaired by after-sales service | 1. Check the connection between display and motor 2. Change Display 3. Change motor controller unit |
13 | LORACommunicationLost | 0x32 | Stop motor output | Lora Communication issue | 1. Deal by user. a. Re-power the e-bike 2. Repaired by after-sales service | 1. Check the connection between lora and motor 2. Change Lora module 3. Change motor controller unit |
14 | CommunicationCRCError | 0x01 | Stop motor output | Motor Communication issue | 1. Deal by user. a. Re-power the e-bike 2. Repaired by after-sales service | 1. Change Display 2. Change motor controller unit |
15 | MotorESTError | 0x40 | Stop motor output | Motor issue | 1. Deal by user. a. Re-power the e-bike 2. Repaired by after-sales service | 1. Change motor controller unit |
16 | MotorOverPeakCurrent | 0x41 | Stop motor output | Motor issue | 1. Deal by user. a. Re-power the e-bike 2. Repaired by after-sales service | 1. Change motor controller unit |
17 | MotorLossPhase | 0xC2 | Stop motor output | Motor issue | 1. Deal by user. a. Re-power the e-bike 2. Repaired by after-sales service | 1. Change motor controller unit |
18 | MotorOverDCCurrent | 0x43 | Stop motor output | Motor issue | 1. Deal by user. a. Re-power the e-bike 2. Repaired by after-sales service | 1. Change motor controller unit |
19 | BatteryOverVoltage | 0xD0 | Stop motor output | Battery issue | 1. Deal by user a. Re-power the e-bike b. Charge for the e-bike 2. Repaired by after-sales service | 1. Update e-bike information 2. Change Display 3. Change motor controller unit 4. Change battery |
20 | BatteryLowVoltage | 0x51 | Stop motor output | Battery issue | 1. Deal by user a. Re-power the e-bike b. Charge for the e-bike 2. Repaired by after-sales service | 1. Update e-bike information 2. Change Display 3. Change motor controller unit 4. Change battery |
21 | BatteryOverCurrent | 0x52 | Stop motor output | Motor issue | 1. Deal by user. a. Re-power the e-bike 2. Repaired by after-sales service | 1. Change motor controller unit |
22 | BatteryVersionError | 0xE0 | Stop motor output | Battery issue | 1. Deal by user. a. Re-power the e-bike 2. Repaired by after-sales service | 1. Update e-bike information 2. Change Display 3. Change motor controller unit 4. Change battery |
23 | DisplayVersionError | 0xE5 | Stop motor output | Display issue | 1. Deal by user. a. Re-power the e-bike 2. Repaired by after-sales service | 1. Update e-bike information 2. Change Display 3. Change motor controller unit |